Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1394677.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 07/24/2019 2
Initial Penalty: $5,304.00
Current Penalty: $2,500.00
Issuance Date: 06/06/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0317500
Contest Date:
Final Order: 06/27/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/27/2019 | $2,500.00 | 07/24/2019 | Serious | |
Penalty | Z: Issued | 06/06/2019 | $5,304.00 | 07/24/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Facility, 2319 Beans Cove Road, Clearville, PA: On or about April 19, 2019 the employer did not develop written energy control procedures for all equipment serviced and maintained by employees. Employees service equipment such as, but not limited to: debarker, hog, trimmer, edger and pellet machine. The employer does not have any specific energy control procedures for any of the equipment to ensure employees are protected.