Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1376938.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,282.00
Current Penalty: $0.00
Issuance Date: 06/07/2019
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 07/08/2019
Gravity: 10
Report ID: 0636900
Contest Date:
Final Order: 06/24/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/24/2019 | $0.00 | 07/08/2019 | Serious | |
| Penalty | Z: Issued | 06/07/2019 | $9,282.00 | 07/08/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. On or about January 22, 2019 and at times prior thereto, the employer did not ensure maintenance employees who worked on machines and equipment utilized and followed written lockout/tagout procedures, exposing the maintenance employees to caught in, struck by, amputation and electric shock hazards where they
Translate