Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1372308.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $13,260.00
Issuance Date: 03/05/2019
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/09/2019
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 03/27/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/27/2019 | $13,260.00 | 04/09/2019 | Serious | |
Penalty | Z: Issued | 03/05/2019 | $13,260.00 | 03/14/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 27, 2018, the employer did not utilize energy control procedures for the Mill #3 tube machine. Employees that set-up, clean, and grease the mill machine were exposed to injury in that energy control was not utilized for servicing and maintenance tasks.