Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1371604.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $9,000.00
Issuance Date: 03/12/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/22/2019
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 03/28/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/28/2019 | $9,000.00 | 03/22/2019 | Serious | |
Penalty | Z: Issued | 03/12/2019 | $13,260.00 | 03/22/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Pelletizer #003; On or about January 10, 2019 and at times prior thereto the employer exposed employees to potential hazardous energies in that employees were allowed to work on the pelletizer(s) to clean and clear jams on the cutter without shutting it down and unplugging it in accordance with the company's Energy Control program established procedures.