Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1370996.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 05/02/2019 2
Initial Penalty: $7,577.00
Current Penalty: $5,682.75
Issuance Date: 04/12/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 04/22/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/22/2019 | $5,682.75 | 05/02/2019 | Serious | |
Penalty | Z: Issued | 04/12/2019 | $7,577.00 | 05/02/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. At the conveyor belt "54 Merge", on or about 1/11/19: An overhead pulley located above the conveyor belt crossover was not guarded against accidental contact. Abatement certification must be submitted for this item.