Violation Detail
Standard Cited: 19260451 C01 II General requirements.
Inspection Nr: 1369997.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 06/10/2019 2
Initial Penalty: $7,246.00
Current Penalty: $6,500.00
Issuance Date: 05/23/2019
Nr Instances: 2
Nr Exposed: 3
Related Event Code (REC): A;R
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 06/05/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/05/2019 | $6,500.00 | 06/10/2019 | Serious | |
Penalty | Z: Issued | 05/23/2019 | $7,246.00 | 06/10/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.451(c)(1)(ii): Supported scaffolds with a height to base width ratio of more than four to one (4:1) were not restrained from tipping by installing guys, ties, and braces at the closest horizontal member to the 4:1 height and were not installed at each end of the scaffold: a) Supported Scaffold Northwest Entrance - On or about January 8, 2019, a Biljax brand supported scaffold with a height to base width ratio of more than four to one (4:1) was not restrained from tipping by installing guys, ties, and braces at the closest horizontal member to the 4:1 height. b) Supported Scaffold Northwest Entrance - On or about January 8, 2019, a Biljax brand supported scaffold with a height to base width ratio of more than four to one (4:1) was not restrained from tipping by installing guys, ties, and braces at each end of the scaffold.