Violation Detail
Standard Cited: 19100023 C11 Ladders.
Inspection Nr: 1367214.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $5,529.00
Issuance Date: 03/21/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/02/2019
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 04/15/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/15/2019 | $5,529.00 | 09/02/2019 | Serious | |
| Penalty | Z: Issued | 03/21/2019 | $13,260.00 | 04/18/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.23(c)(11): (11) Portable ladders used to gain access to an upper landing surface have side rails that extend at least 3 feet (0.9 m) above the upper landing surface. On or about December 19, 2018, employees were exposed to fall hazards using a portable ladder that did not extend 3 feet above the landing surface to access a working platform that was 7 feet above the concrete floor on the Astraflex Press #4.