Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1347122.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,054.00
Current Penalty: $4,527.00
Issuance Date: 11/20/2018
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 01/09/2019
Gravity: 10
Report ID: 0112600
Contest Date:
Final Order: 12/07/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/07/2018 | $4,527.00 | 01/09/2019 | Serious | |
| Penalty | Z: Issued | 11/20/2018 | $9,054.00 | 01/09/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: 14 Mechanic St, Southbridge, MA: On September 18, 2018 and at times prior, employees who performed maintenance on equipment and machine operator employees who unjammed and made adjustments to belt ribbons did not utilize energy control procedures. On September 18, 2018, two maintenance employees working on the Chicago Ironing Folding Machine placed one lock on the electrical energy source, but did not lock either the pneumatic or flammable gas energy sources.