Violation Detail
Standard Cited: 19260703 A02 Requirements for cast-in-place Concrete.
Inspection Nr: 1342888.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,934.00
Current Penalty: $11,934.00
Issuance Date: 02/28/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 04/16/2019
Gravity: 10
Report ID: 0420600
Contest Date: 03/20/2019
Final Order: 04/02/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/02/2020 | $11,934.00 | 04/16/2019 | Serious | |
Penalty | C: Contested | 04/25/2019 | $11,934.00 | 04/16/2019 | Serious | |
Penalty | Z: Issued | 02/28/2019 | $11,934.00 | 04/16/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.703(a)(2): Drawings or plans, including all revisions, for the jack layout, formwork (including shoring equipment), working decks, and scaffolds were not available at the jobsite: a) At the site located at 14900 Chelonia Pkwy, Orlando, FL 32821, the employer used outdated drawings for embedding bolts and brackets into shear wall (21) and without approval from the shoring engineer and the structural engineer of record, on or about August 29, 2018.