Violation Detail
Standard Cited: 19260600 A06 I Equipment.
Inspection Nr: 1334024.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $12,934.00
Issuance Date: 12/20/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 01/17/2019
Gravity: 10
Report ID: 0830300
Contest Date:
Final Order: 01/28/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/28/2019 | $12,934.00 | 01/17/2019 | Serious | |
| Penalty | Z: Issued | 12/20/2018 | $12,934.00 | 01/17/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.600(a)(6)(i): For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment: (a) On or about July 23, 2018 and at times prior for the employees exposed to electrical shock hazards where a GEHL RS12-42 struck a 14,000 volt electrical line while loading water tank sections onto a flatbed truck, in the vicinity of Highway 1806 & 115 Avenue NW, near Watford City, North Dakota.