Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1322264.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 10/29/2018 2
Initial Penalty: $9,054.00
Current Penalty: $5,000.00
Issuance Date: 10/12/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0627100
Contest Date: 11/08/2018
Final Order: 03/06/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/06/2019 | $5,000.00 | 10/29/2018 | Serious | |
Penalty | C: Contested | 11/09/2018 | $9,054.00 | 10/29/2018 | Serious | |
Penalty | Z: Issued | 10/12/2018 | $9,054.00 | 10/29/2018 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. The Employer failed to conduct periodic inspection of the energy control procedure on the scrap winder to ensure that procedures were being followed by employees attaching the scrap metal edge to the winder drum.