Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1277323.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,054.00
Current Penalty: $0.00
Issuance Date: 01/18/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/24/2018
Gravity: 10
Report ID: 0111700
Contest Date:
Final Order: 02/02/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/02/2018 | $0.00 | 01/24/2018 | Serious | |
| Penalty | Z: Issued | 01/18/2018 | $9,054.00 | 01/24/2018 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources: a. Overhead door #9 - On or about November 10, 2017, an employee received a serious amputation injury while performing maintenance on the Liftmaster (model MT5011U S/N 4614N9029) overhead door opener, where the power source was not physically located, isolated and deenergized prior to beginning the maintenance procedures.