Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1265531.015
Citation: 01001A
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $11,641.00
Current Penalty: $11,641.00
Issuance Date: 03/22/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity:
Report ID: 0317300
Contest Date: 06/13/2018
Final Order: 07/27/2018
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 07/27/2018 | $11,641.00 | Other | ||
| Penalty | C: Contested | 06/14/2018 | $11,641.00 | Serious | ||
| Penalty | Z: Issued | 03/22/2018 | $11,641.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(7)(i): Training was not provided to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: (a) 1162 Holly Hill Road, Milford, DE - On or about September 22, 2017, the employer failed to ensure that employees clearly understood the applicability of the employer's Lockout/Tagout program for production versus maintenance operations, as the provided training did not address inspection, on the ZED Thermoformer machine.