Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1253269.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,675.00
Current Penalty: $8,872.50
Issuance Date: 10/04/2017
Nr Instances: 1
Nr Exposed: 35
Abatement Date: 10/17/2017
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 10/24/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/24/2017 | $8,872.50 | 10/17/2017 | Serious | |
| Penalty | Z: Issued | 10/04/2017 | $12,675.00 | 10/17/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance as required by 29 CFR 1910.147(c)(4)(ii)[A]-[D]: a. The employer's lockout/tagout procedure for Vessel 8, did not clearly identify all the specific steps to be followed by authorized employees to isolate, relieve residual energy, and disable all hazardous energy sources, such as air pressure, prior to and throughout performing service and maintenance activities. The procedure also lacked specific verification steps to determine the effectiveness of the energy control measures.