Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1244119.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $8,873.00
Issuance Date: 11/15/2017
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 01/15/2018
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 12/11/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/11/2017 | $8,873.00 | 01/15/2018 | Serious | |
| Penalty | Z: Issued | 11/15/2017 | $8,873.00 | 12/05/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a. On or about June 29, 2017, located at the Fanuc gantry robot located in the Heat Treat and Paint Department on Paint Line #1, the employer did not develop, document and utilize lockout/tagout procedures for the control of hazardous energy as per 1910.147(c)(4)(ii), thereby exposing the employees to the release of stored energy and/or the unexpected startup of equipment.