Violation Detail
Standard Cited: 19100147 F01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1243791.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,675.00
Current Penalty: $12,675.00
Issuance Date: 09/28/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/06/2017
Gravity: 10
Report ID: 0418300
Contest Date:
Final Order: 10/25/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 09/28/2017 | $12,675.00 | 10/06/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(f)(1): The sequence of actions required by 29 CFR 1910.147(f)(1) when testing or positioning of machines, where temporary removal of lockout or tagout devices from the energy isolating device is required, were not followed: (a) On or about 6/23/2017 - at Edge Bander EB008 machine, an employee was in the danger zone to observe testing and positioning for snipping unit malfunction.