Violation Detail
Standard Cited: 19100134 C01 Respiratory Protection.
Inspection Nr: 1243236.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,339.00
Current Penalty: $3,478.00
Issuance Date: 12/15/2017
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/19/2018
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 01/17/2018
Related Event Code (REC): C
Emphasis:
Substance: 1591
Substance: C141
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/17/2018 | $3,478.00 | 01/19/2018 | Serious | |
Penalty | Z: Issued | 12/15/2017 | $6,339.00 | 01/12/2018 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program, including worksite specific procedures and all applicable provisions of this section, in the workplace where respirators were required by the employer as necessary to protect the health of the employee. a) On June 28, 2017, eWorks Electronic Services, Inc. did not establish and implement a written respiratory protection program when employees working on the Cathode Ray Tube Line and in the Bulb Crushing Area were required to wear Home Depot HDX H950S N-95 respirators.