Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1242624.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,054.00
Current Penalty: $7,392.00
Issuance Date: 09/14/2017
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/02/2018
Gravity: 5
Report ID: 0213900
Contest Date:
Final Order: 10/03/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/03/2017 | $7,392.00 | 01/02/2018 | Serious | |
| Penalty | Z: Issued | 09/14/2017 | $9,054.00 | 10/11/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) Seabrook Brothers Co. Inc.- Throughout the Company: The employer did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment including but not limited to; the MDicer / Square chopping machine. Occurred on or about 06/20/2017.
Translate