Violation Detail
Standard Cited: 19100218 A02 Forging machines.
Inspection Nr: 1219428.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $8,000.00
Issuance Date: 07/13/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 08/02/2017
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 07/27/2017
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/27/2017 | $8,000.00 | 08/02/2017 | Serious | |
| Penalty | Z: Issued | 07/13/2017 | $8,873.00 | 08/02/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.218(a)(2): Inspection and maintenance. It shall be the responsibility of the employer to maintain all forge shop equipment in a condition which will insure continued safe operation. On or about March 23, 2017, the employer did not inspect and maintain the safe condition of a point of operation protection device (metal prop). The metal prop is used as a safeguard device between the upper ram and the anvil during die changes at the CECO 20C gravity drop hammer.