Violation Detail
Standard Cited: 19100134 C01 Respiratory Protection.
Inspection Nr: 1219220.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,873.00
Current Penalty: $4,000.00
Issuance Date: 09/11/2017
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/27/2017
Gravity: 10
Report ID: 0524200
Contest Date: 10/02/2017
Final Order: 04/05/2018
Related Event Code (REC): C
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/05/2018 | $4,000.00 | 10/27/2017 | Serious | |
Penalty | C: Contested | 10/05/2017 | $8,873.00 | 10/27/2017 | Serious | |
Penalty | Z: Issued | 09/11/2017 | $8,873.00 | 10/27/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.103: NOTE: The requirements applicable to construction work under this section are identical to those set forth at 29 CFR 1910.134 of this chapter. 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: W. Congress Pkwy and S. Jefferson St. Chicago, IL 60607 - Clausen Structures, Inc. did not ensure that a written respiratory protection program was established and implemented for those employees required to wear respiratory protection, including MSA half-face, negative pressure air-purifying respirators equipped with GME-P100 cartridges, and an Allegro EZ Air Pro Blue Headtop supplied-air respirator. a) On or about March 15, 2017, employees were required to wear MSA half-face, negative pressure air-purifying respirators equipped with GME-P100 cartridges while performing air arcing and torch burning to remove existing bearings on a steel bridge structure. b) On March 29, 2017, an employee was required to wear an Allegro EZ Air Pro Blue Headtop supplied-air respirator while performing air arcing to remove existing bearings on a steel bridge structure. The respiratory protection program shall include, at a minimum, procedures for selecting respirators; medical evaluations; fit testing; procedures for proper use in routine and reasonably foreseeable emergency situations; procedures for cleaning, storing, inspecting, repairing and discarding respirators; employee training regarding respiratory hazards they are exposed to, proper uses and limitations of respirators; and procedures for regularly evaluating the effectiveness of the respirator program. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.