Violation Detail
Standard Cited: 19260020 B02 General safety and health provisions.
Inspection Nr: 1183716.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 02/13/2017 2
Initial Penalty: $8,873.00
Current Penalty: $8,873.00
Issuance Date: 02/07/2017
Nr Instances: 4
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/24/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/24/2017 | $8,873.00 | 02/13/2017 | Serious | |
Penalty | Z: Issued | 02/07/2017 | $8,873.00 | 02/13/2017 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. Located within Sequence 17 Music Wing on October 10 and/or 11, 2016 Table A type short span open web steel bar joist series 22K7-J240 and 22K9-J237 both exceeding 40 foot 7 inches span were erected with crane supported load lines releasing joist load prior to being welded on both sides of the seat of one end of each steel joist and bolted diagonal erection bridging being installed and anchored without the competent person maintaining performance of inspections on bar joist series type and spans based on Table A of 1926.757 and Partial Roof Joist Erection Plan J2.21 to determine and ensure during the erection, attachment open web steel joist required open web steel bar joist seat welding and bolted erection bridging connections were in place prior to release of load lines.