Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1167637.015
Citation: 01001A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $12,471.00
Current Penalty: $9,750.00
Issuance Date: 08/25/2016
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 03/08/2018
Gravity:
Report ID: 0418300
Contest Date: 09/19/2016
Final Order: 06/08/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 06/08/2017 | $9,750.00 | 03/08/2018 | Other | |
Penalty | C: Contested | 09/23/2016 | $12,471.00 | 09/07/2016 | Serious | |
Penalty | Z: Issued | 08/25/2016 | $12,471.00 | 09/07/2016 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 08/01/2016 - Maintenance department, an employee performing electrical work on machinery such as, but not limited to, a Battenfield injection molding, TR-US 02 with 480 VAC , pneumatic pressure, and gravitational sources of energy was doing so without a specific procedure for locking and tagging out the machinery. b) On or about 08/01/2016 - Maintenance department, an employee performing mechanical work on machinery such as, but not limited to, the potting machine with electrical, pneumatic, and gravitational sources of energy was doing so without a specific procedure for locking and tagging out the machinery. c) On or about 08/01/2016 - Maintenance department, an employee performing maintenance work on machinery such as, but not limited to, the drill machinery with electrical and pneumatic sources of energy was doing so without a specific procedure for locking and tagging out the machinery.