Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1151535.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,346.00
Current Penalty: $9,259.00
Issuance Date: 10/05/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/18/2016
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 10/27/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/27/2016 | $9,259.00 | 10/18/2016 | Serious | |
Penalty | Z: Issued | 10/05/2016 | $12,346.00 | 10/18/2016 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about May 27, 2016, at the laser cutting work cell, the maintenance work that was done on the laser 2 shuttle was done with the shuttle and the overhead gantry crane not locked out. The lock out tag out procedure that had been developed for the FMS System was not utilized.