Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1139294.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,930.00
Current Penalty: $4,000.00
Issuance Date: 05/13/2016
Nr Instances: 4
Nr Exposed: 4
Abatement Date: 08/11/2016
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 06/03/2016
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/03/2016 | $4,000.00 | 08/11/2016 | Serious | |
| Penalty | Z: Issued | 05/13/2016 | $6,930.00 | 06/11/2016 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about April 7, 2016, employees performing set-up activities on the PC-8 machine were not required to utilize energy control procedures to prevent employee exposure to hazardous energy from the movement of machine components. The employer had not developed and implemented energy control procedures to ensure that throughout the machine set-up activity including machine adjustments, employees were protected from hazardous energy.