Violation Detail
Standard Cited: 19261412 A01
Inspection Nr: 1129879.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,520.00
Current Penalty: $2,520.00
Issuance Date: 07/29/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/15/2016
Gravity: 10
Report ID: 0627100
Contest Date: 08/15/2016
Final Order: 02/13/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/13/2017 | $2,520.00 | 08/15/2016 | Serious | |
Penalty | C: Contested | 08/15/2016 | $2,520.00 | 08/15/2016 | Serious | |
Penalty | Z: Issued | 07/29/2016 | $2,520.00 | 08/15/2016 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1926.1412(a)(1): Equipment that has had modifications or additions which affect the safe operation of the equipment (such as modifications or additions involving a safety device or operational aid, critical part of a control system, power plant, braking system, load-sustaining structural components, load hook, or in-use operating mechanism) or capacity must be inspected by a qualified person after such modifications/additions have been completed, prior to initial use. The inspection must meet all of the following requirements: The employer did not ensure that the modifications or additions to the Manitowoc Boom Truck outrigger/stabilizer hydraulic line(s) were inspected by a qualified person.