Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1070072.015
Citation: 01001A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 09/17/2015
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/13/2015
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 10/14/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/17/2015 | $7,000.00 | 10/13/2015 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) At the workplace, the employer did not ensure that employee(s), that were authorized in lockout/tagout, performed and/or observed periodic inspections of the energy control procedures for machines such as, but not limited to the Line 8 Douglas Case Packer Machine at least annually.