Violation Detail
Standard Cited: 19260451 E01 General requirements.
Inspection Nr: 977523.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $1,600.00
Current Penalty: $1,120.00
Issuance Date: 06/11/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0214200
Contest Date:
Final Order: 07/07/2014
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/07/2014 | $1,120.00 | Serious | ||
Penalty | Z: Issued | 06/11/2014 | $1,600.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a. 1767 Route 10 East Morris Plains, NJ Safe access and egress to the JLG Aerial Lift was not provided. Employees were observed accessing the aerial lift from a welded tubular frame scaffold work platform using the cross braces. Violation observed on or about 05/19/2014