Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 960768.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $3,400.00
Current Penalty: $3,400.00
Issuance Date: 06/26/2014
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 07/16/2014
Gravity:
Report ID: 0627500
Contest Date:
Final Order: 07/21/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/21/2014 | $3,400.00 | 07/16/2014 | Other | |
| Penalty | Z: Issued | 06/26/2014 | $3,400.00 | 07/16/2014 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Rig #759: on or about February 25, 20214, the shaft guard was missing from between the diesel motor and generating plant on all three generators, exposing employees to caught-in hazards.