Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 951537.015
Citation: 01001
Citation Type: Repeat
Abatement Status: Abatement Completed
Initial Penalty: $63,000.00
Current Penalty: $48,000.00
Issuance Date: 01/15/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/22/2014
Gravity: 10
Report ID: 0626600
Contest Date: 01/30/2014
Final Order: 04/17/2015
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | R: Review Commission | 04/17/2015 | $48,000.00 | 01/22/2014 | Repeat | |
| Penalty | C: Contested | 02/06/2014 | $63,000.00 | 01/22/2014 | Willful | |
| Penalty | Z: Issued | 01/15/2014 | $63,000.00 | 01/22/2014 | Willful |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: The employer does not ensure that employees are protected from cave-ins while working in excavations. This violation occurred on or about December 05, 2013, when employees were exposed to cave-in hazards while working in an excavation without an adequate protective system. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all excavations that employees are required to work are protected by an adequate protective system designed in accordance with paragraph (b) or (c) of this section.