Violation Detail
Standard Cited: 19260451 A06 General requirements.
Inspection Nr: 936636.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 01/22/2014
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/24/2014
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 02/18/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/18/2014 | $7,000.00 | 01/24/2014 | Serious | |
| Penalty | Z: Issued | 01/22/2014 | $7,000.00 | 01/24/2014 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person: a) In elevator shaft 2, on or about August 29, 2013, a scaffold used to construct the shaft had been altered from its design, exposing employees to fall hazards.