Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 913231.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $4,000.00
Current Penalty: $2,200.00
Issuance Date: 07/30/2013
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/23/2013
Gravity:
Report ID: 0728900
Contest Date:
Final Order: 08/14/2013
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/14/2013 | $2,200.00 | 08/23/2013 | Other | |
Penalty | Z: Issued | 07/30/2013 | $4,000.00 | 08/23/2013 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: In the Tire Lube Express (TLE) pit area the employer is failing to ensure that the 4 ceiling mounted heater fans were provided with guards that have an opening no larger than one-half inch.