Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 911768.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,500.00
Current Penalty: $5,500.00
Issuance Date: 11/26/2013
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/09/2013
Gravity: 5
Report ID: 0418800
Contest Date: 12/19/2013
Final Order: 12/13/2013
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 12/26/2013 | $5,500.00 | 12/09/2013 | Serious | |
Penalty | R: Review Commission | 12/13/2013 | $5,500.00 | 12/09/2013 | Serious | |
Penalty | Z: Issued | 11/26/2013 | $5,500.00 | 12/09/2013 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a. On or about September 10, 2013, at the above addressed jobsite, the employer failed to establish and follow specific energy control procedures in accordance with manufacturer's developed guidelines, to ensure the securing/blocking of the powered industrial truck's fork carriage/mast when working under an elevated mast.