Violation Detail
Standard Cited: 19100303 G02 I General.
Inspection Nr: 907135.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $2,380.00
Current Penalty: $1,428.00
Issuance Date: 07/12/2013
Nr Instances: 12
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 07/31/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/31/2013 | $1,428.00 | Serious | ||
Penalty | Z: Issued | 07/12/2013 | $2,380.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures. a. In the compressor room where employees check refrigeration equipment, the meat prep electrical door was open, thereby exposing employees to a contact hazard. b. In the compressor room where employees check refrigeration equipment, the ice cream electrical door was open, thereby exposing employees to a contact hazard. c. In the compressor room where employees check refrigeration equipment, the walk in freezer electrical door was open, thereby exposing employees to a contact hazard. d. In the compressor room where employees check refrigeration equipment, the 24 foot M/D dairy electrical door was open, thereby exposing employees to a contact hazard. e. In the compressor room where employees check refrigeration equipment, the 24 foot fresh meat electrical door was open, thereby exposing employees to a contact hazard. f. In the compressor room where employees check refrigeration equipment, the 24 foot end cap electrical door was open, thereby exposing employees to a contact hazard. g. In the compressor room where employees check refrigeration equipment, the 24 foot frozen meat electrical door was open, thereby exposing employees to a contact hazard. h. In the compressor room where employees check refrigeration equipment, the frozen rear end cap electrical door was open, thereby exposing employees to a contact hazard. I. In the compressor room where employees check refrigeration equipment, the 36 foot produce electrical door was open, thereby exposing employees to a contact hazard. j. In the compressor room where employees check refrigeration equipment, the smoked meat electrical door was open, thereby exposing employees to a contact hazard. k. In the compressor room where employees check refrigeration equipment, the electrical cover for the thermostat control, on the north wall behind the door, was off, thereby exposing employees to a contact hazard. l. In the compressor room where employees check refrigeration equipment, the electrical cover for the thermostat control, on the north wall above the defrost controls, was off, thereby exposing employees to a contact hazard.