Violation Detail
Standard Cited: 19260404 F06 Wiring design and protection.
Inspection Nr: 902734.015
Citation: 01001
Citation Type: Serious
Abatement Date: 06/25/2013 7
Initial Penalty: $1,600.00
Current Penalty: $1,600.00
Issuance Date: 06/13/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0418200
Contest Date:
Final Order: 07/11/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 06/13/2013 | $1,600.00 | 06/25/2013 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) Front side, new residential construction located at 2744 Carrick Court, Powder Springs, GA 30127: Employee was exposed to electric shock hazards while using an Emglo (Model K15A-8P) 5.5HP 8-Gallon Electric Wheelbarrow Compressor which was plugged into the temporary electric service with a missing ground pin.