Violation Detail
Standard Cited: 19100101 B Compressed gases (general requirements).
Inspection Nr: 848883.015
Citation: 01001
Citation Type: Serious
Abatement Date: 05/22/2013 2
Initial Penalty: $7,000.00
Current Penalty: $6,300.00
Issuance Date: 05/03/2013
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC): R
Gravity: 10
Report ID: 0317300
Contest Date:
Final Order: 05/20/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/20/2013 | $6,300.00 | 05/22/2013 | Serious | |
Penalty | Z: Issued | 05/03/2013 | $7,000.00 | 05/22/2013 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.101(b) - Compress Gas Association Pamphlet P-1-1965, Section 3.1.12: Compressed gas cylinders were not handled inaccordance with Compressed Gas Association Pamphlet P-1-1965 and were subjected to a temperature above 125 degrees and permitted to come in contact with a flame on any part of a compressed gas cylinder. Vapor Combustion Unit - Eight (8) liquid propane gas cylinders covered by a tarpaulin were subjected to a temperature above 125 degrees as these cylinders were heated by steam pumped through a hose under the tarpaulin. On or about January 24, 2013.