Violation Detail
Standard Cited: 19100146 D09 Permit-required confined spaces
Inspection Nr: 721561.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $7,000.00
Issuance Date: 04/26/2013
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/14/2013
Gravity: 10
Report ID: 0627700
Contest Date:
Final Order: 05/29/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/29/2013 | $7,000.00 | 06/14/2013 | Serious | |
| Penalty | Z: Issued | 04/26/2013 | $7,000.00 | 05/20/2013 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency service, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue: On or about November 03, 2012, the employer did not ensure procedures for summoning rescue and emergency services, rescuing entrants from permit spaces, providing necessary emergency services to rescued employees or preventing unauthorized personnel from attempting a rescue to eliminate or control the hazards created when a permit-required confined space rescue was needed during welding operations conducted in the elliptical head of a moisture separator unit.