Violation Detail
Standard Cited: 19260305 C Jacks-lever and ratchet, screw, and hydraulic.
Inspection Nr: 429591.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,080.00
Current Penalty: $3,080.00
Issuance Date: 08/09/2012
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 08/24/2012
Gravity: 10
Report ID: 0111100
Contest Date: 08/22/2012
Final Order: 10/18/2013
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 10/18/2013 | $3,080.00 | 08/24/2012 | Serious | |
| Penalty | C: Contested | 08/23/2012 | $3,080.00 | 08/24/2012 | Serious | |
| Penalty | Z: Issued | 08/09/2012 | $3,080.00 | 08/24/2012 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.305(c): When it was necessary to provide a firm foundation, the base of the jack was not blocked or cribbed securely. A wood block was not placed between the cap and the load where there was a possibility of slippage of the metal cap of the jack: a) Underneath East Side of Summer Cottage - Employer failed to provide a firm foundation to adequately support four Pro-lift 12 ton automotive bottle jacks. The 4 jacks were piled on blocks, supporting the structure, on soft, unleveled, and unstable ground. The base of the four automotive bottle jacks was placed on 8" x 8" x 2" blocks piled 8 high and the blocks were on top of a 6" x 6"x 2' pressure treated block setting on water saturated ground. b) Summer Cottage - The employer used 6 1/4 " by 7" by 1/4 " metal plates between jack cap/saddle and load of structure; increasing the probability of slippage.