Violation Detail
Standard Cited: 19260502 B03 Fall protection systems criteria and practices.
Inspection Nr: 411823.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,800.00
Current Penalty: $1,120.00
Issuance Date: 10/26/2012
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0316100
Contest Date: 11/19/2012
Final Order: 01/04/2013
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 01/04/2013 | $1,120.00 | Serious | ||
| Penalty | C: Contested | 11/30/2012 | $2,800.00 | Serious | ||
| Penalty | Z: Issued | 10/26/2012 | $2,800.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.502(b)(3): Guardrail systems shall be capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge. a) Third floor Balcony, West side of Building B - Two employees were working from behind a temporary guardrail hoisting permanent balcony guardrails up to the 3rd floor balcony. One worker leaned on the temporary guardrail which caused one of the temporary guardrail posts to release from the balcony floor and he fell 21 feet onto the concrete pad below.