Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 314851940

Citation: 01001

Citation Type: Serious

Abatement Status: X

Initial Penalty: $3,300.00

Current Penalty: $1,500.00

Issuance Date: 03/30/2012

Nr Instances: 2

Nr Exposed: 10

Abatement Date: 08/30/2012

Gravity: 05

Report ID: 0524500

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 04/24/2012 $1,500.00 08/30/2012 Serious  
Penalty Z: Issued 03/30/2012 $3,300.00 05/16/2012 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: UNCLASS

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment that were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to toxic anhydrous ammonia inhalation hazards in the event of an uncontrolled release originating from the ammonia machinery room: Machinery room - On or about November 8, 2011, employees were not adequately protected against the potential release of anhydrous ammonia in that: a)The machinery room was not isolated from other work areas to prevent the migration of anhydrous ammonia b)There was not sufficient means to warn employees working throughout the facility in the event of an ammonia release Among other methods, feasible and acceptable methods to control these hazards are to adhere to the safe design, installation, and operation of anhydrous ammonia refrigeration systems as prescribed by ANSI/ASHRAE 15-2007, "Safety Standard for Refrigeration Systems", specifically: a.Separate the space containing the refrigeration machinery from other occupancies by tight construction with tight fitting, self-closing fire doors. (Section 8.11.2) b.Install an ammonia detector set to alarm at a value not greater than the American Conference of Governmental Industrial Hygienist (ACGIH), Threshhold Limit Value (TLV), time-weighted average (TWA) (currently 35 ppm) and that actuates a visual and audible alarm that warns both inside and outside each entrance to the machinery room. (Section 8.11.2.1) c.Provide legible permanent signs, securely attached and easily accessible, reading "Machinery Room - Authorized Personnel Only", communicating that entry is forbidden except by personnel trained in emergency procedures invoked by activation of the ammonia alarm. (Section 8.11.8) d.Tightly seal pipes piercing the interior walls of the machinery room to the walls, ceiling or floor through which they pass. (Section 8.12) e.Install equipment to provide inlet air to replace that being exhausted. (Section 8.11.4) f.Ensure there is no airflow to or from an occupied space through a machinery room unless the air is ducted and sealed in such a manner as to prevent any refrigerant leakage from entering the airstream. (Section 8.11.7) ***Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c)***

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close