Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 314660135

Citation: 01001

Citation Type: Serious

Abatement Status: X

Initial Penalty: $2,380.00

Current Penalty: $1,300.00

Issuance Date: 02/10/2011

Nr Instances: 2

Nr Exposed: 2

Abatement Date: 02/23/2011

Gravity: 05

Report ID: 0830500

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 03/01/2011 $1,300.00 02/23/2011 Serious  
Penalty Z: Issued 02/10/2011 $2,380.00 02/23/2011 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: FALLING

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falls of 8 to 10 feet while working from an unsafe platform: (a)Barvista Building Systems, 390 Mountain View Road, Berthoud, CO 80513; On and before October 26, 2010, an employee using a hand router to cut sections of sheet rock surrounding a door frame entering a bathroom was observed utilizing the top and next to last steps of an 8 ft stepladder as a working platform, contrary to the use for which the ladder was intended. This condition exposed employee to a fall hazard of up to 8 feet. (b)Barvista Building Systems, 390 Mountain View Road, Berthoud, CO 80513: On and before October 26, 2010, an employee using a pneumatic nail gun to complete a section of roof joists was observed utilizing the top and next to last steps of a 10 foot step ladder as a working platform, contrary to the use for which the ladder was intended. Condition exposed employee to a fall hazard of up to 10 feet. Among other methods, one feasible and acceptable abatement method to correct this hazard is to perform the following: ANSI A14.2-2007, American National Standards Institute, Inc., Section 8.2.1.3.2 Stepladders (Proper Size). The highest standing level is constant for a specific stepladder. Typical relationships are as follows: Stepladder Recommended Highest (size ft) Standing Level 4 1 ft, 11 inches 5 2 ft, 10 inches to 11 inches 6 3 ft, 10 inches 7 4 ft, 9 inches to 10 inches 8 5 ft, 9 inches to 10 inches 10 7 ft, 8 inches to 9 inches The maximum working height is then established by adding the users height and safe reach to the highest standing level dimension. NOTE: The ANSI A14.2-2007 standard can be obtained on line at http://webstore.ansi.org/RecordDetail.aspx?sku=ANSI+ASC+A14.5-2007 and should be used as a referenced when training employees on the safe use and operation of ladders. Abatement Note: Abatement certification is required for this item (See enclosed "Sample Abatement-Certification Letter").

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close