Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 314267303
Citation: 01001
Citation Type: Serious
Abatement Status: X
Initial Penalty: $2,975.00
Current Penalty: $2,231.00
Issuance Date: 04/13/2011
Nr Instances: 5
Nr Exposed: 2
Abatement Date: 04/27/2011
Gravity: 05
Report ID: 0418800
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/26/2011 | $2,231.00 | 04/27/2011 | Serious | |
| Penalty | Z: Issued | 04/13/2011 | $2,975.00 | 04/27/2011 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard: STRUCK BY
Section 5(a)1 of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: On or about 11/16/2010, at Pelican Wire Co., Naples, FL. a. At the maintenance department, an employee was exposed to caught by and struck by hazards while working with a lathe (Birmingham, Model CT-144G) that lacked a provision to prevent automatic restart upon restoration of power. b. At the maintenance department, an employee was exposed to caught by and struck by hazards while working with a milling machine (Bridgeport, Model 8F) that lacked a provision to prevent automatic restart upon restoration of power. c. At the maintenance department, an employee was exposed to caught by and struck by hazards while working with a milling machine (Ultima, Property #111003) that lacked a provision to prevent automatic restart upon restoration of power. d. At the maintenance department, an employee was exposed to caught by and struck by hazards while working with a drill press (Walker-Turner, Serial #111017) that lacked a provision to prevent automatic restart upon restoration of power. e. At the maintenance department, an employee was exposed to caught by and struck by hazards while working with a lathe (Enco, Model 111-1450) that lacked a provision to prevent automatic restart upon restoration of power. Among the feasible and useful methods to correct the hazard is installing a magnetic switch to prevent automatic restart upon restoration of power after a power failure. Note:Certification of abatement must be submitted for this citation item.ion
Translate