Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 313064487

Citation: 01001

Citation Type: Serious

Abatement Status: X

Initial Penalty: $2,125.00

Current Penalty: $1,062.50

Issuance Date: 06/03/2009

Nr Instances: 1

Nr Exposed: 1

Abatement Date: 08/31/2009

Gravity: 03

Report ID: 0134000

Contest Date:

Final Order:

Related Event Code (REC): R

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 06/23/2009 $1,062.50 08/31/2009 Serious  
Penalty Z: Issued 06/03/2009 $2,125.00 07/21/2009 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: UNAPEQUIP

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of overexposure to anhydrous ammonia: (a) Location - Engine Room: On or about 4/16/09, low pressure receiver V7 was not inspected as often as required by an outside party. (b) Location - Engine Room: On or about 4/16/09, the company did not have information about low pressure receiver V7, including but not limited to Manufacturer's name, serial number, model number, maximum allowable pressure, and test pressure applied. Among other methods, a feasible method to eliminate or reduce this hazard is to have an inspection conducted of the receiver at least once every five years by an outside party, as mandated by International Institute of Ammonia Refrigeration (IIAR) Bulletin No. 110, Guidelines for Start-up, Inspection and Maintenance of Ammonia Mechanical Refrigerating Systems, Section 6.4.4.1. The insulation may be removed to allow name plate inspection, with subsequent repair and insulation plug provided to cover name plate area and to provide future access, as (IIAR 109, Guidelines for IIAR Minimum Safety Criteria for a Safe Ammonia Refrigeration System, Sections 4.3.1.2 and 4.3.4).

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close