Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

This violation item has been deleted.

Inspection Nr: 311718928

Citation: 01001

Citation Type: Serious

Abatement Status:

Initial Penalty: $3,500.00

Current Penalty: $3,500.00

Issuance Date: 06/17/2008

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 07/07/2008

Gravity: 10

Report ID: 0524200

Contest Date:

Final Order:

Related Event Code (REC): A

Emphasis:

Substance: 0560


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 07/09/2008 $3,500.00 07/07/2008 Serious  
Penalty Z: Issued 06/17/2008 $3,500.00 07/07/2008 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: HEAT

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to accumulated fuel gases and potential fire, and oxygen deficient atmospheres. a) Peacock Oil Company, South Equipment Room - Gas utilization equipment including: Raypak Heating Boiler, Model 724 WT-B, Serial Number 0988106022; Raypak Heating Boiler, Model 516T, Serial Number 1278103800TP; and, Dayton Unit Heater, Model 3E226A, Serial Number C8412734, installed in buildings: Required air was not supplied for combustion and ventilation, nor for comfort and proper working conditions for personnel. One feasible means of abatement, among others is to provide the space with two permanent openings to the outdoors, one commencing within 12 inches of the top and one commencing within 12 inches of the bottom of the enclosure and which conforms to NFPA 54 - National Fuel Gas Code. NFPA 54 (1988) states that the "openings shall communicate directly or by ducts, with the outdoors or spaces (crawl or attic) that freely communicate with the outdoors. When directly communicating with the outdoors, for example, each opening shall have a minimum free area of 1 square inch per 4000 BTU per hour of total input rating of all equipment in the enclosure." (Chapter 5.3.3) In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close