Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 311681183

Citation: 01001

Citation Type: Serious

Abatement Status: I

Initial Penalty: $1,500.00

Current Penalty: $1,400.00

Issuance Date: 08/07/2009

Nr Instances: 1

Nr Exposed: 3

Abatement Date: 08/12/2009

Gravity: 03

Report ID: 0316400

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 08/26/2009 $1,400.00 08/12/2009 Serious  
Penalty Z: Issued 08/07/2009 $1,500.00 08/12/2009 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: CRUSHING

Section 5(a)(1) of the Occupational Safety & health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to employees exposed to crushing injuries in the event of a collapse of the wooden trusses: (a)Structure 1 / 3 Units: The employer had only 1 lateral temporary top chord brace on each side of the 6 in 12 sloped 31 foot wooden trusses and one gable brace in lieu of following the BCSI B1 Summary Sheet which calls for 2 top chord lateral bracing along with diagonal bracing and a gable brace at each location of the lateral braces as observed on 7-16-09. (b)Structure 2 / 3 Units: The employer had only 1 lateral temporary top chord brace on each side of the 6 in 12 sloped 31 foot wooden trusses and one gable brace in lieu of following the BCSI B1 Summary Sheet which calls for 2 top chord lateral bracing along with diagonal bracing and a gable brace at each location of the lateral braces as observed on 7-16-09. (c)Structure 3 / 4 Units: The employer had only 1 lateral temporary top chord brace on each side of the 6 in 12 sloped 31 foot wooden trusses and one gable brace in lieu of following the BCSI B1 Summary Sheet which calls for 2 top chord lateral bracing along with diagonal bracing and a gable brace at each location of the lateral braces as observed on 7-16-09. Abatement Note: Among other methods, one feasible and acceptable abatement to correct this hazard would be to follow the appropriate BCSI guide lines for temporary bracing of wooden trusses.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close