Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

This violation item has been deleted.

Inspection Nr: 311425474

Citation: 01001

Citation Type: Serious

Abatement Status:

Initial Penalty: $6,300.00

Current Penalty:

Issuance Date: 05/05/2008

Nr Instances: 1

Nr Exposed: 145

Abatement Date: 06/07/2008

Gravity: 10

Report ID: 0134000

Contest Date: 05/27/2008

Final Order: 12/19/2008

Related Event Code (REC): A

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 12/19/2008 06/07/2008 Serious  
Penalty Z: Issued 05/05/2008 $6,300.00 06/07/2008 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: BURNS

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of burns and bodily injury from the hot ash and steam from leaking or ruptured pressure-retaining items. The following conditions contributed to the existence of the hazard: a) Location - Boiler House, Unit #3: On or about November 6, 2007 Dominion Energy New England operated a pressurized coal fired Babcock & Wilcox that was insufficiently inspected and examined in the lower vestibule/dead air space which contains steam at approximately 600 Degrees Fahrenheit under 1000 psig. Three employees were fatally injured on November 6, 2007, when the boiler tubes ruptured in the lower vestibule/dead air space. * The lower vestibule/dead air space had not been entered and inspected in over 9 years. No appropriate testing had been preformed to determine the conditions in the lower vestibule/dead air space in that length of time. * Ash was allowed to accumulate in the lower vestibule/dead air space over a long period which does not allow for entry into and inspection of that area. Among other methods, feasible means of abatement would be to: 1. Conduct Operation, Care/Maintenance, and Inspection of power boilers following the most recent National Codes such as ANSI/NB-23, ASME Section 7 Care of Power Boilers and guidance from Electric Power Research Institute and the manufacturer, Babcock and Wilcox. Including cleaning out the ash and debris from the vestibule/dead air space to allow for the inspection. 2. Determine a lower vestibule/lower dead air space inspection interval based on sound engineering principles and scientific data. 3. Install alarm system associated with power boiler operating parameters (eg., feed water make-up, electrostatic precipitator load/current changes, boiler pH, furnace pressure, boiler sodium and leaks in vestibules). 4. Install Leak Acoustic Monitoring system in vestibules.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close