Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 310468152

Citation: 01001

Citation Type: Serious

Abatement Status: X

Initial Penalty: $3,500.00

Current Penalty: $2,100.00

Issuance Date: 01/03/2008

Nr Instances: 1

Nr Exposed: 5

Abatement Date: 01/30/2008

Gravity: 10

Report ID: 0830500

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 01/24/2008 $2,100.00 01/30/2008 Serious  
Penalty Z: Issued 01/03/2008 $3,500.00 01/30/2008 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: STRUCK BY

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards due to failure of running wire rope within the air tugger: (a)All Star Enterprises, Inc. dba Bernard Well Service & Rig # 3 County Rd 352, Rifle, CO 81650: On or before July 19, 2007, the casing contractor did not ensure that frequent and periodic inspections were performed for the wire rope used to transfer casing pipe from the laydown machine to the rig floor. The casing contractor did not have sufficient procedures and controls implemented to effectively ensure running rope and trough equipment used to transfer joints of casing pipe, was inspected frequently and periodically to determine if wire rope was sufficient for use. The wire rope used had multiple breaks within a lay identified through the entire rope being used. The condition exposed employees working on the derrick floor and on the lay down machine to struck-by hazards as a result of the wire rope failing. Abatement Note: Among other methods, one feasible and acceptable method to correct this hazard can be found in the American National Standards Institute B.30.7-2001 Section 7- 2.1,7-2.1.2, 7-2.1.4, and 7-2.4, which provides for frequent and periodic inspections and the recordkeeping associated with such inspections. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.