Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 308479443

Citation: 01001

Citation Type: Serious

Abatement Status: X

Initial Penalty: $3,500.00

Current Penalty: $1,750.00

Issuance Date: 02/01/2007

Nr Instances: 2

Nr Exposed: 4

Abatement Date: 08/10/2007

Gravity: 10

Report ID: 0316700

Contest Date:

Final Order:

Related Event Code (REC): C

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty P: Petition to Mod Abatement 07/26/2007 $1,750.00 08/10/2007 Serious  
Penalty I: Informal Settlement 02/08/2007 $1,750.00 07/06/2007 Serious  
Penalty Z: Issued 02/01/2007 $3,500.00 03/06/2007 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: DUST&FUMES

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of fire and explosion: (a)Raw Materials, Wash Line - The duct work from the dryer on the titanium wash line was not cleaned frequently enough because accumulations of material, containing titanium, had collected inside the duct, on or about October 12, 2006. (b)Raw Materials, Wash Line - The employer had the dry-type cyclone dust collector for the dryer of the titanium wash line located inside the building, on or about October 12, 2006. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct these hazards includes complying with National Fire Protection Association (NFPA) 484, Standard for Combustible Metals (2006), including, but not limited to: -Cleaning the interior of ducts regularly where the possibility of build up of titanium or other combustible material exists to ensure internal cleanliness as listed in Paragraphs 10.4.8.3 and 10.4.8.9 of NFPA 484-2006. -Locating dry-type cyclone dust collectors outside of buildings as listed in Paragraph 10.4.8.2 of NFPA 484-2006. VERIFICATION REQUIRED

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.