Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 307570093
Citation: 01001
Citation Type: Serious
Abatement Status: I
Initial Penalty: $750.00
Current Penalty: $375.00
Issuance Date: 09/07/2004
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 09/10/2004
Gravity: 03
Report ID: 0112300
Contest Date:
Final Order:
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/27/2004 | $375.00 | 09/10/2004 | Serious | |
| Penalty | Z: Issued | 09/07/2004 | $750.00 | 09/10/2004 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard: STRUCK BY
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by falling trusses as a result of inadequate temporary truss bracing during installation. The first truss installed was not provided with proper ground bracing and the remaining trusses were not provided with proper lateral and diagonal bracing made out of 2 x 4 lumber. Among other methods, feasible and acceptable abatement methods to correct this hazard include complying with the Building Component Safety Information booklet, BCSI-B2 Summary Sheet - Truss Installation and Temporary Bracing, which is published by the Wood Truss Council of America and the Truss Plate Institute.