Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 307010421

Citation: 01001

Citation Type: Serious

Abatement Status: X

Initial Penalty: $525.00

Current Penalty: $315.00

Issuance Date: 01/09/2006

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 02/03/2006

Gravity: 01

Report ID: 0627400

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 01/17/2006 $315.00 02/03/2006 Serious  
Penalty Z: Issued 01/09/2006 $525.00 02/03/2006 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: ELECTRIC

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the condition(s) listed below: Oasis Gin Inc., 810 County Road 331, Seminole, TX. For the period of time up to and including 01/06/06, employees were not protected from electrical hazards due to the following conditions: A flexible cord was used instead of permanent wiring. This cord passed through two switch boxes without protection. Under the National Electric Code (NEC 2005), Article 547.5(D) states "Where necessary to employ flexible connections, dusttight flexible connectors, liquidtight flexible conduit, or flexible cord listed and identified for hard usage shall be used. All connectors and fittings used shall be listed and identified for the purpose." Under the National Electric Code (NEC 2005), Article 547.5(C)(1) states "Equipment enclosures, boxes, conduit bodies, and fittings installed in areas of buildings where excessive dust may be present shall be designed to minimize the entrance of dust and shall have not openings (such as holes for attachment screws) through which dust could enter the enclosure. One feasible and acceptable abatement method would be to ensure all electrical equipment is installed / maintained in accordance with Article 547 of the National Electric Code. "Pursuant to 29 CFR 1903.19(d), the employer must provide documentation that this violation has been abated within 10 calendar days after the abatement date."ent

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close