Text For Citation: 01 Item/Group: 001 Hazard: UNAPOPPROC
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: Employees were exposed to the hazard of truss collapse due to the lack of truss bracing. Among other methods, feasible and acceptable abatement methods to correct this hazard would be to: Comply with the Wood Truss Council of America: "Temporary erection bracing must be applied to three planes of the roof system to ensure stability: Plane 1) Top Chord (sheathing), Plane 2) Bottom Chord (ceiling plane), and Plane 3) Web Member plane or vertical plane perpindicular to trusses. Also, comply with the Truss Plate Institute's HIB-91 for trusses that span over 60' where the truss erection contractor must "See a registered professional engineer."